<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>STRATUS SAFETY PORTAL &#187; groundwater</title>
	<atom:link href="http://www.stratussafety.net/?feed=rss2&#038;tag=groundwater" rel="self" type="application/rss+xml" />
	<link>http://www.stratussafety.net</link>
	<description>If you don’t know what is going to happen, there is no way to stop it. Plan ahead for safety.</description>
	<lastBuildDate>Fri, 20 Dec 2019 22:51:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.2.39</generator>
	<item>
		<title>Hose Failure on a Groundwater Extraction System</title>
		<link>http://www.stratussafety.net/?p=45</link>
		<comments>http://www.stratussafety.net/?p=45#comments</comments>
		<pubDate>Thu, 02 Sep 2010 00:15:42 +0000</pubDate>
		<dc:creator><![CDATA[Administrator]]></dc:creator>
				<category><![CDATA[Incidents]]></category>
		<category><![CDATA[groundwater]]></category>
		<category><![CDATA[GW]]></category>
		<category><![CDATA[hose failure]]></category>
		<category><![CDATA[o&m]]></category>
		<category><![CDATA[spill]]></category>
		<category><![CDATA[system]]></category>

		<guid isPermaLink="false">http://www.stratussafety.net/?p=45</guid>
		<description><![CDATA[At 4:14 am on August 25, 2010, the clerk at USA 234 (Santa Ana) called the Stratus emergency phone number to report water spraying from the groundwater treatment system compound. Stratus staff received the call from the emergency phone number, &#8230; <a href="http://www.stratussafety.net/?p=45">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
				<content:encoded><![CDATA[<p>At 4:14 am on August 25, 2010, the clerk at USA 234 (Santa Ana) called the Stratus emergency phone number to report water spraying from the groundwater treatment system compound. <span id="more-45"></span>Stratus staff received the call from the emergency phone number, and Stratus was on site at approximately 4:45 am.  Stratus observed approximately 5 gallons of water on the concrete paving east of the compound, but no water from the system was observed to have flowed off-site. The system was immediatly shut down at the main power supply.  Additional staff arrived at 4:55 am, the compound was unlocked and the concrete inside was found to be damp but there was no ponded water.  An obvious source of the leak could not initially be identified.  The system was temporarily reactivated, and a pinhole leak was discovered in the process hose at the outlet of the manifold (between the manifold and the inlet of the first carbon vessel). The system was then shut down and lock out/tag out (LOTO) was applied pending replacement of the damaged hose.</p>
<p>Additional details can be read through the secure login under the Incident and Near Miss Projects.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.stratussafety.net/?feed=rss2&#038;p=45</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Incident-Release from Groundwater Extraction System</title>
		<link>http://www.stratussafety.net/?p=69</link>
		<comments>http://www.stratussafety.net/?p=69#comments</comments>
		<pubDate>Sat, 26 Jun 2010 01:06:38 +0000</pubDate>
		<dc:creator><![CDATA[Administrator]]></dc:creator>
				<category><![CDATA[Incidents]]></category>
		<category><![CDATA[groundwater]]></category>
		<category><![CDATA[GW]]></category>
		<category><![CDATA[o&m]]></category>
		<category><![CDATA[spill]]></category>
		<category><![CDATA[system]]></category>

		<guid isPermaLink="false">http://www.stratussafety.net/?p=69</guid>
		<description><![CDATA[At 9:35 the morning of June 24, 2010, Stratus was notified via the emergency phone number that water was leaking from the groundwater treatment system compound at ARCO 6160.At 10:00 am Stratus personnel were on-site to turn the power off to the &#8230; <a href="http://www.stratussafety.net/?p=69">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
				<content:encoded><![CDATA[<p>At 9:35 the morning of June 24, 2010, Stratus was notified via the emergency phone number that water was leaking from the groundwater treatment system compound at ARCO 6160.<span id="more-69"></span>At 10:00 am Stratus personnel were on-site to turn the power off to the remediation compound and stop the pumping of any additional groundwater. Initial observations indicated water leaking from the secondary containment berm, however, no overflow conditions or releases were evident with the equipment.  A vacuum truck was on-site by 11:45 to remove residual water in and around the compound.     </p>
<p>Additional details can be read through the secure login under the Incident and Near Miss Projects.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.stratussafety.net/?feed=rss2&#038;p=69</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
